Deactivators

CSE pro and CSE nova deactivators

 

Product description
CSE deactivators are liquid substances used for manufacturing concrete components with exposed surfaces. The surface-acting deactivators allow one to obtain the effect of uncovered aggregate using the washed concrete method with all available wash depth values. Our offer spans two types of deactivators: thinner-based CSE pro and water-based CSE nova; both can be used in even the toughest conditions. The CSE pro and CSE nova deactivators are environmentally-friendly products, fully bio-degradable if used properly. They are economic and easy to use, they may be sprayed on, are quick-drying, and can be used with all kinds of formwork. The CSE pro and CSE nova products are reliable even at ambient temperatures of up to 30 °C.


Usage
CSE deactivators are used on concrete surfaces used at pre-casting plants or directly at the construction site. They may be used for all kinds of formwork, in particular for structural formwork with curved outer surfaces.

Mode of use
Before use, the CSE deactivators must be thoroughly mixed using mixing implements. The preparation may be applied using one of two methods. The first one entails introduction of the product to the form surface. For this purpose, the form surface has to be covered evenly with the liquid using a painter's roller or paintbrush. After the substance has dried, the form may be filled with concrete. The second method entails application onto a fresh concrete surface. It is best to use a spray gun for this purpose. Note that during this procedure, no puddles of the product should be allowed to form on the surface.
It is advantageous to cover up the sprayed surface. The selection of proper application method should be made after practical trials, meaning - samples must be made, which will correspond to actual manufacturing conditions with respect to the concrete mix recipe, the production course and time, component thickness and resulting binding temperature. The concrete recipe or density and texture should be so that sedimentation does not occur quickly and for the binding speed not to be too high. The concrete binding process should not begin earlier than 60 minutes after it is applied.
Heating of the form should begin an hour after the concrete is packed at the earliest. All parameters determined during this trial should precisely correspond to manufacture conditions as much as possible. The packing operation should begin not later than 45 minutes after the concrete mix is introduced into the form, and the exact time should be determined by trials. The concrete component should be washed between eight and 72 hours, however this should also be preceded by trials.
It is important to maintain an appropriate washing rhythm for a given series. The components should remain in forms until the washing operation begins, unless one would want to reduce the washing depth somewhat. In such a case, the components may be subjected to influence by air within a trial-and-error-determined time of 2-8 hours until the washing commences. Following that, the concrete surfaces need to be washed using a pressure washer, and this will uncover the decorative aggregate. Another method of uncovering the decorative aggregate is brushing and flushing with running water.


Final result

CSE pro deactivators

Symbol
Color
Fraction
[mm]
Flushing depth
[mm]
Unit
Package/
Sales unit
Art. no.
CSE pro 05
blue
0-4
ok. 0,3
1 kg
container/20 kg
CH-DE-00-0-02700
CSE pro 01
blue
0-4/8
ok. 0,5
1 kg
container/20 kg
CH-DE-00-0-02701
CSE pro 02
brown
2-4/8
ok. 1,0
1 kg
container/20 kg
CH-DE-00-0-02702
CSE pro 10
green
4-8
ok. 1,5
1 kg
container/20 kg
CH-DE-00-0-02703
CSE pro 25
yellow
4-8
ok. 2,0
1 kg
container/20 kg
CH-DE-00-0-02706
CSE pro 50
pink
6-8/12
ok. 2,5
1 kg
container/20 kg
CH-DE-00-0-02709
CSE pro 70
gray
8-16
ok. 3,0
1 kg
container/20 kg
CH-DE-00-0-02710
CSE pro 130
white
8-16/22
ok. 4,0
1 kg
container/20 kg
CH-DE-00-0-02704
CSE pro 200
orange
12-16/32
ok. 5,0
1 kg
container/20 kg
CH-DE-00-0-02705
CSE pro 300
violet
16-32
ok. 6,0
1 kg container/20 kg CH-DE-00-0-02707
CSE pro 400
violet
16-32/54
ok. 7,0
1 kg container/20 kg CH-DE-00-0-02708
CSE nova deactivators

Symbol
Color
Fraction
[mm]
Flushing depth
[mm]
Unit
Package/
Sales unit
Art. no.
CSE nova 005
blue
0-4
ok. 0,3
1 kg
container/20 kg
CH-DE-00-0-02689
CSE nova 01
blue
0-4/8
ok. 0,5
1 kg
container/20 kg
CH-DE-00-0-02690
CSE nova 02
brown
2-4/8
ok. 1,0
1 kg
container/20 kg
CH-DE-00-0-02691
CSE nova 10
green
4-8
ok. 1,5
1 kg
container/20 kg
CH-DE-00-0-02692
CSE nova 25
yellow
4-8
ok. 2,0
1 kg
container/20 kg
CH-DE-00-0-02695
CSE nova 50
pink
6-8/12
ok. 2,5
1 kg
container/20 kg
CH-DE-00-0-02698
CSE nova 70
gray
8-16
ok. 3,0
1 kg
container/20 kg
CH-DE-00-0-02699
CSE nova 130
white
8-16/22
ok. 4,0
1 kg
container/20 kg
CH-DE-00-0-02693
CSE nova 200
orange 12-16/32
ok. 5,0
1 kg
container/20 kg
CH-DE-00-0-02694
CSE nova 300
violet
16-32
ok. 6,0
1 kg container/20 kg CH-DE-00-0-02696
CSE nova 400
violet
16-32/54
ok. 7,0
1 kg container/20 kg CH-DE-00-0-02697


Effectiveness / storage
Effectiveness: 1 kg for approx. 10-15 m2 of formwork or form surface.
Store in tightly closed containers in a cool and ventilated space.

 


RSE, SE, WB deactivation paper sheets



 

Product description
The RSE, SE and WB paper sheets are deactivation solutions in paper form, used during manufacture of decorative concrete surfaces with the application of the washed concrete method. Reliable and precise, it guarantees the manufacture of high-quality products.

Application
For the production of i. e. pedestrian walkway tiles, cladding tiles, stair components (treads) using the washed concrete method.

Mode of use

1) Prepare an appropriate required product volume, the size and 'washing' depth. then insert the paper into the form with the inscriptions facing downwards.
2) and 3) Next, fill the form with the concrete mix. In this example, the form shall be subjected to hermetic processing in a press.
4) Not more than 24 hours later, the formwork and the paper should be removed.
5) The part surface should be washed using a pressure washer.

Package
Standard formats (250 sq m in a cardboard box)
400 x 200 mm; 400 x 400 mm; 400 x 600 mm; 400 x 800 mm; 500 x 250 mm; 500 x 500 mm; 500 x 750 mm; 1000 x 1000 mm
Standard roll widths (length: 100 running metres):
1000 mm; 1200 mm; 1500 mm; 1600 mm

Note!
Standard formats are reduced by 1 mm in one axis and 2 mm in the other axis against the standard provided measurements, i. e. the 400 mm x 400 mm sheet is actually 398 mm x 399 mm in size.


Final result

RSE, SE, WB deactivation paper sheets
Symbol
Aggregate diameter
Φ[mm]

Flushing depth
[mm]
Unit
Package/
Sales unit
Art. no.
Papier RSE 01-k
0 - 4/8
0,5

Box/250 m²
CH-DE-00-0-02721
Papier RSE 01-r
0 - 4/8
0,5
Roll/100 mb
CH-DE-00-0-02722
Papier SE 01-k
0 - 4/8
0,7

Box/250 m²
CH-DE-00-0-02726
Papier SE 01-r
0 - 4/8
0,7

Roll/100 mb
CH-DE-00-0-02727
Papier WB-k gray
2 - 5
1-2

Box/250 m² CH-DE-00-0-02731
Papier WB-r gray
2 - 5 1-2

Roll/100 mb
CH-DE-00-0-02732
Papier WB-k yellow
4 - 8
2

Box/250 m² CH-DE-00-0-02741
Papier WB-r yellow
4 - 8
2

Roll/100 mb CH-DE-00-0-02742
Papier WB-k blue
8 - 12
2-4

Box/250 m² CH-DE-00-0-02716
Papier WB-r blue
8 - 12
2-4
Roll/100 mb CH-DE-00-0-02717
Papier WB-k green
8 - 16
3-5
Box/250 m² CH-DE-00-0-02736
Papier WB-r green
8 - 16
3-5

Roll/100 mb
CH-DE-00-0-02737
Papier WB-k red
16 - 32
5-8

Box/250 m² CH-DE-00-0-02711
Papier WB-r red
16 - 32
5-8

Roll/100 mb
CH-DE-00-0-02712

 

 

Microgel deactivator


Product description
The microgel contains surfactants and acid ingredients for light washing (deacidification) of already hardened concrete surfaces. Methods used earlier, spanning deacidification of the concrete surface with hydrochloric acid and similar acids, as a result of vertical flowing or surface concentrations, caused unevenness on the concrete surface. The Microgel, thanks to its gel form, leads to very even wash spots on the concrete surface, and it may be used without difficulty on vertical surfaces. Usage of the product on horizontal pre-cast concrete components also allows the penetration phase to remain uniform, and the final result is improved.
Thanks to the use of high-quality ingredients in the Microgel, the process water does not contain any nitrogen compounds, and iron content is very low. If the Microgel is used correctly, then active substances become neutralised biologically between the acid Microgel ingredients and the alkali concrete surface. For this reason the water used for washing of the surface after the Microgel is applied, if used in a sufficient volume, will not lead to a marked change of pH values.

Usage
Microgel is used to flush away mortar from the concrete surface in order to uncover decorative aggregate.

Mode of use
The processed concrete components should not be older than five days. Before Microgel is used, the concrete should be saturated with water. Then, the ready prepared product should be thoroughly mixed and applied onto the processed concrete component with a paintbrush or any different brush. After several seconds of action of the preparation, the surface should be brushed with a hard brush and finally generously flushed with water. If the required washing depth is not obtained, process a part of the surface or the entire surface again. To conclude, wash the component with a high-pressure washer, if possible, using warm water.

Effectiveness/storage
Economy ca. 200 g/m2.
Keep in a cool and dry place

Final result

Microgel deactivator
Symbol
Unit
Package/
Sales unit
Art. no.
Microgel
kg
bucket/20 kg